Disclosure: Some product links are affiliate or referral links. As an Amazon Associate, Weld Support Parts earns from qualifying purchases. Other marketplace links may also earn a commission at no extra cost to you. Learn more.

Centralized weld fume extraction system

Miller FILTAIR 8000 Machine Support

Eight-pack centralized weld fume extraction system for high-capacity multi-source installations.

Centralized fume-extraction fitment check. AY/3.4 describes these as engineered systems. Confirm airflow, filter configuration, indoor/outdoor package, electrical service, ducting, and installation requirements with Miller or a qualified fume-extraction specialist before ordering.

Start Here

Use this page for the Miller FILTAIR 8000 model path, then match shared replacement parts and engineered options.

Plan the installation

Indoor, rooftop, and outdoor packages have different layout, control, weather, and installation requirements.

Miller FILTAIR 8000 Snapshot

Model-specific values from AY/3.4. Equipment stock numbers are not listed in the supplied document.

SpecValue
ModelMiller FILTAIR 8000
Nominal airflow range2,500-7,000 cfm (1,180-3,304 L/sec.)
Filter packs8
Number of valves8
Input power230, 460, or 575 V, 3-phase, 60 Hz
Sound level72-75 dBA at 5 ft.; peak pulse cleaning is 92.7 dBA at 5 ft.
DimensionsA 135 in. x B 37.2 in. x C 83.2 in. (3,429 x 945 x 2,113 mm)
Shipping weight2,900 lb. (1,315 kg)
Motor options shown in performance data15 hp or 20 hp
Compressed air80-100 psi for the automatic cleaning system

Model / Ordering Path

AY/3.4 leaves the extractor stock-number fields blank. Use the model name and the required engineered configuration when requesting a quote.

ModelOrdering statusNext step
Miller FILTAIR 8000No stock number listed in AY/3.4Review FILTAIR family or contact Miller/distributor for configuration and quote

Shared Replacement Parts and Arms

The same numbered filters, arms, ZoneFlow arms, and mounting kits are listed across the centralized family. Match arm diameter and length before ordering.

PartDescriptionTypeBuy / lookup
300927Replacement high-efficiency filter, all modelsReplacement filterSearch Amazon Site lookup
300933Replacement HEPA filter, models with HEPA optionReplacement filterSearch Amazon Site lookup
3012426 in. telescoping extraction arm, 3-4.5 ft.Extraction armSearch Amazon Site lookup
3012378 in. telescoping extraction arm, 3-4.5 ft.Extraction armSearch Amazon Site lookup
3009536 in. standard extraction arm, 7 ft.Extraction armSearch Amazon Site lookup
3009546 in. standard extraction arm, 10 ft.Extraction armSearch Amazon Site lookup
3009556 in. standard extraction arm, 12 ft.Extraction armSearch Amazon Site lookup
3009808 in. standard extraction arm, 7 ft.Extraction armSearch Amazon Site lookup
3009818 in. standard extraction arm, 10 ft.Extraction armSearch Amazon Site lookup
3009828 in. standard extraction arm, 12 ft.Extraction armSearch Amazon Site lookup
9518106 in. ZoneFlow arm with motor control box, 10 ft.ZoneFlow armSearch Amazon Site lookup
9518116 in. ZoneFlow arm with motor control box, 12 ft.ZoneFlow armSearch Amazon Site lookup
9517588 in. ZoneFlow arm with motor control box, 10 ft.ZoneFlow armSearch Amazon Site lookup
9517598 in. ZoneFlow arm with motor control box, 12 ft.ZoneFlow armSearch Amazon Site lookup
300952Arm mounting bracket and ducting kit for 6 in. armsMounting kitSearch Amazon Site lookup
300771Arm mounting bracket and ducting kit for 8 in. armsMounting kitSearch Amazon Site lookup

Configured Options and Services

These AY/3.4 options do not have a stock number in the supplied ordering table. Treat them as quote/configuration paths, not exact part-number matches.

OptionDocumented path
Weather hoodOutdoor mounting with outdoor exhaust; no stock number is listed in AY/3.4.
FILTAIR low profile hoodAvailable from 4 x 4 ft. through 16 x 16 ft. in one-foot increments; quote/configure. Review hood configurations
Spark CoolerUses extractor airflow to cool sparks; quote/configure.
DuctingQuick-fit clamp-together style; quote/configure.
Installation servicesMiller lists installation services in the ordering section; quote/configure.

Installation Notes

The document describes three installation environments and different requirements for outdoor packages.

Installation detailDocumented note
Mounting environmentsIndoor, rooftop, or outdoor pad installations are shown.
Outdoor packageWind-load and seismic-rated outdoor models include a remote-mounted control box and optional weather hood.
Air inletTop or front air inlet configuration.
Filter cleaningLinear Jet Automatic Cleaning System pulses particulate from the filter media.
System planningHave a certified industrial hygienist test facility air to determine equipment requirements and protection from contaminants.

Source: Miller Electric FILTAIR 4000-12000 Industrial Centralized Systems specification sheet AY/3.4, issued June 2019, pages 1-8. Machine and accessory descriptions are transcribed from the supplied Miller document. The document does not list stock numbers for the four extractors; model paths are quote/configuration support. Amazon buttons are optional buying aids, and direct buttons are limited to approved registry matches.

Need More Help?Open related Miller FILTAIR and PPE support paths.
Miller FILTAIR familyFILTAIR accessoriesPPE fume extractionFind My PartPAPR / Respiratory